Support

[UniServer 1522/2524/2544/3526/3546 & 1512/1522LV, UniWorkstation 5528/5548 & 4514]

How to update BMC firmware :
1. Boot to DOS
2. Execute command A:\SRVxxx.bat for Server or A:\WSxxx.bat for Workstation.
3. then update firmware finished. for your system.

Note:
Before using IPMI feature, user has to set network parameter for BMC in CMOS setup.

Version Description Download

1.12
[6/03/08]

1. Support SysFAIL LED on front panel of UniWorkstation 5528/5548

WHTFM112.zip

1.11
[6/27/07]

1. Change PSU FAN & DC LED function
2. Fix sensor reading fail when changing threshold value
3. Change Reset pin default to input pin

WHTFM111.zip

1.08
[6/4/07]

1. 2U configuration added
2. Use SDK V27
3. SOL flash screen performance is better
4. Fix BIOS SETUP rescan same line in escape box
5. Fix can not login local linux issue
6. Fix SOL suspend then activate fail issue.
7. Fix CPU2FAN & CPU3FAN sometimes have abnormal SEL log issue.
8. Change BMC retry time from 1 second to 0.3 second.

WHTFM108.zip
1.04
[10/12/06]

1. Use SDK V21.
2. Modify temperature sensor non critical threshold from 50 to 65 degree.
3. Modify Get Device Info product ID from 00 20 to 02 00(LS byte first).
4. Modify SDR assert and dessert event mask from 3FFF to 7A95.

WHTF104a.zip

[UniServer 1512]

How to update BMC firmware :
1. Boot to DOS
2. Execute command A:\fw.bat
3. then update firmware finished. for your system.

Note:
Before using IPMI feature, user has to set network parameter for BMC in CMOS setup.

Version Description Download

3.83
[01/09/09]

  1. Modify the Vcore range to follow AMD spec
  2. Fan de-assertion lost issue
  3. Update SDK to B0019
1512v383.zip

3.70
[01/15/08]

  1. Fix BMC failure after BMC reset
  2. Modify Vcore range to follow AMD specification
  3. Modify CPU seonsor's minimum in SDR
1512v370.zip

3.61
[11/23/07]

  1. The first release
1512v361.zip

[UniWorkstation 4514]

How to update BMC firmware :
1. Boot to DOS
2. Execute command A:\fw.bat
3. then update firmware finished. for your system.

Note:
Before using IPMI feature, user has to set network parameter for BMC in CMOS setup.

Version Description Download

6.81
[01/15/08]

  1. Fix BMC failure after BMC reset
  2. Modify Vcore range to follow AMD specification
  3. Modify CPU seonsor's minimum in SDR
  4. Lower RPM range threshold for fan
4514v681.zip

3.61
[11/23/07]

  1. The first release
4514v661.zip

[UniServer 1522LV]

How to update BMC firmware :
1. Boot to DOS
2. Execute command A:\9280fw.bat
3. then update firmware finished. for your system.

Note:
Before using IPMI feature, user has to set network parameter for BMC in CMOS setup.

Version Description Download

1.0
[06/26/08]

  1. The first release
bmc100.zip