| [UniServer 1522/2524/2544/3526/3546 & 1512/1522LV, UniWorkstation 5528/5548 & 4514]
How to update BMC firmware :
1. Boot to DOS
2.
Execute command A:\SRVxxx.bat for Server or A:\WSxxx.bat for Workstation.
3.
then update firmware finished. for your system.
Note:
Before using IPMI feature, user has to set network parameter for BMC in CMOS setup.
|
Version |
Description |
Download |
1.12
[6/03/08]
|
1. Support SysFAIL LED on front panel of UniWorkstation 5528/5548
|
WHTFM112.zip |
1.11
[6/27/07]
|
1. Change PSU FAN & DC LED function
2. Fix sensor reading fail when changing threshold value
3. Change Reset pin default to input pin
|
WHTFM111.zip |
1.08
[6/4/07] |
1.
2U configuration added
2. Use SDK V27
3. SOL flash screen
performance is better
4. Fix BIOS SETUP rescan
same line in escape
box
5. Fix can not login
local linux issue
6. Fix SOL suspend then
activate fail issue.
7. Fix CPU2FAN &
CPU3FAN sometimes have
abnormal SEL log issue.
8. Change BMC retry
time from 1 second to
0.3 second.
|
WHTFM108.zip |
1.04
[10/12/06] |
1. Use
SDK V21.
2. Modify temperature
sensor non critical
threshold from 50 to
65 degree.
3. Modify Get Device
Info product ID from
00 20 to 02 00(LS byte
first).
4. Modify SDR assert
and dessert event mask
from 3FFF to 7A95. |
WHTF104a.zip |
|
[UniServer 1512]
How to update BMC firmware :
1. Boot to DOS
2.
Execute command A:\fw.bat
3.
then update firmware finished. for your system.
Note:
Before using IPMI feature, user has to set network parameter for BMC in CMOS setup.
| Version |
Description |
Download |
3.83
[01/09/09] |
- Modify the Vcore range to follow AMD spec
- Fan de-assertion lost issue
- Update SDK to B0019
|
1512v383.zip |
3.70
[01/15/08] |
- Fix BMC failure after BMC reset
- Modify Vcore range to follow AMD specification
- Modify CPU seonsor's minimum in SDR
|
1512v370.zip |
3.61
[11/23/07]
|
- The first release
|
1512v361.zip |
|
[UniWorkstation 4514]
How to update BMC firmware :
1. Boot to DOS
2.
Execute command A:\fw.bat
3.
then update firmware finished. for your system.
Note:
Before using IPMI feature, user has to set network parameter for BMC in CMOS setup.
| Version |
Description |
Download |
6.81
[01/15/08] |
- Fix BMC failure after BMC reset
- Modify Vcore range to follow AMD specification
- Modify CPU seonsor's minimum in SDR
- Lower RPM range threshold for fan
|
4514v681.zip |
3.61
[11/23/07]
|
- The first release
|
4514v661.zip |
|
[UniServer 1522LV]
How to update BMC firmware :
1. Boot to DOS
2.
Execute command A:\9280fw.bat
3.
then update firmware finished. for your system.
Note:
Before using IPMI feature, user has to set network parameter for BMC in CMOS setup.
| Version |
Description |
Download |
1.0
[06/26/08]
|
- The first release
|
bmc100.zip |
|
|